Location 66 (L066)

NOTE: Locations L060 through L089 are time clock related programs. The optional Steffes Time Clock Module must be installed in order to utilize the features described in these locations

Factory

Default

Default

Range

Description / Function

0:00

0:00 to 23:45

All Systems

Version 2.08 and lower: Weekday Peak Time #3 - Specifies the time (military) at which the 3rd peak period is to begin each weekday (Monday - Friday).

0:00

0:00 to 23:45

Version 2.10 and Higher: Start Time #3 - If L060 does not include the 16 bit: 3rd Weekday Peak or A-Peak start time: Sets start time of the 3rd weekday scheduled Peak or Anticipated Peak period (mode and duration set in L067). Value specified in 15-minute intervals.

If L060 includes the 16 bit: 3rd Winter Peak or A-Peak start time:

Using the annual schedule, this value sets the start time for the mode and duration as set in L067 and applies to every day following the 1st day of the month selected in L058 (first day of "winter") until the 1st day of the month selected in L059 (first day of "summer").

This setting applies to weekends if L060 contains the 64 bit, otherwise weekends are off-peak continuously.