Value
|
Option Selected
|
0
|
Time clock module not utilized for control purposes.
|
1
|
Enable time clock module to be used for peak control purposes.
|
2
|
Enable time clock module to be used for anticipated peak control purposes (Specialty Applications only.) In version 1.52 and later enables A mode on clock failure.
|
4
|
2100 Series Only - Enables the Steffes Time Clock Module to be used for room temperature setback purposes and adds "Schd" to the menu on the display. "Schd" is the schedule for room temperature setback (L074-L089). "D1sp" is the weekday set point and "D1c1" is the weekday time. "E1sp" is the weekend set point and "E1cl" is the weekend time.
Version 2.10 - "Schd" appears in menu if 32 bit (below) is enabled as well as this 4 bit and only during the first four minutes after power-up.
|
8
|
Enable calendar function, allows user to edit YEAR and Date.
Version 2.10 and later: Required for Seasonal schedule using 16 bit (below).
|
16
|
Enables Specialized Time Schedule - Ont. - Refer to the appropriate configuration guide for more information.
V2.02 - do not use, outdated schedule.
V2.04 and V2.08 - use in conjunction with 8 bit.
Version 2.10 and later: A-Peak and Peak use seasonal schedule in L062 - L073
|
32
|
Clock schedules show "Schd" mini menu. Requires 4 bit also (above) to be used and only appears during the first four minutes after power-up.
|
64
|
Configures the "Schd" menu so changes can be made at the faceplate. Hold the M button in and use the up or down arrow button to change the value. If disabled, changes are made by pressing the up arrow and using the M button to scroll.
Version 2.10 and later: Seasonal schedule is applied to weekends, otherwise weekends will be off-peak continuously.
|