Location 62 (L062)

Configuration 14 (C014)

NOTE: Locations L060 through L089 are time clock related programs. The optional Steffes Time Clock Module must be installed in order to utilize the features described in these locations

Factory

Default

Default

Range

Description / Function

0:00

0:00 to 23:45

All Systems

Version 2.08 and lower: Weekday Peak Time #1 - Specifies the time at which the first peak period is to begin on weekdays (Monday - Friday). The value is set in military time (24-hour clock period).

0:00

0:00 to 23:45

All Systems

Version 2.10 and Higher: Start Time #1 - If L060 does not include the 16 bit: 1st Weekday Peak or A-Peak start time: Sets start time of the 1st weekday scheduled Peak or Anticipated Peak period (mode and duration set in L063). Value specified in 15-minute intervals.

 

If L060 includes the 16 bit: 1st Winter Peak or A-Peak start time:

Using the annual schedule, this value sets the start time for the mode and duration as set in L063 and applies to every day following the 1st day of the month selected in L058 (first day of "winter") until the 1st day of the month selected in L059 (first day of "summer").

 

This setting applies to weekends if L060 contains the 64 bit, otherwise weekends are off-peak continuously.