Optional Controls Configuration - Interfaces the system with optional sensors and controls that may be used in the application. Shortcuts to some user control functions are also enabled in this location.
Value
|
Option Selected
|
1
|
Enable Hard Wired Outdoor Temperature Sensor. (Only applicable if using a charge subroutine of 3, 5, 7, 8 or 9 in L010, L011, L030, and/or L032).
|
2
|
Enable Heater's Room Temperature Sensing System. (Built-in or hard wired remote sensor.)
|
4
|
Enable the Time Clock Module Option and add both "CLOC" and "DAy" to the menu on the display. (Refer to L060-L089 for setting desired function and operation of the time clock module.)
|
8
|
Ability to Enable/Disable Charge Control Override Option from the faceplate. (This option allows user to initiate a one-time full core charge. When utilized, all charge control settings are temporarily overridden to force the heater to its maximum charge during the off-peak period.)
NOTE: This is not a Peak override.
|
16
|
Ability to Enable/Disable "OFF" Mode from the faceplate. (Reference L009.)
|
32
|
2100 Series Only - Ability to Enable/Disable Room Temperature Setback Option from faceplate. (Reference L001.) Not Used in 3100, 4100, or 5100 Series.
|
64
|
2100 Series Only - Ability to Enable/Disable Room Temperature Set Back Editing Option from the faceplate when utilizing the Steffes Time Clock Module.
|
128
|
2100 Series Only - Enable Output Temperature Control. (MUST be enabled in 2100 Series.)
|
|