Specifications - XCVR2

2-Pole

Scroll down to 5-Pole

Scroll down to 3-Phase

Electrical

Control Circuit:

Current

0.2 amps

PLC Transmitter Frequency

13.3 - 15.2 kHz

Low Voltage Input Switch Loading from R terminal to all other low voltage terminals

1.2 mA

Load-Control Relays:

Maximum Controlled Motor Load @ 120VAC

1 HP

Maximum Controlled Motor Load @ 208 or 240 VAC

1.5 HP

NOTE: In single-phase applications, the most effective input voltage is 240/208 VAC. 

Mechanical:

Enclosures Available:

Outdoor

Surface Mount

Indoor Only

Flush or Surface Mount

Features:

Outdoor:

Knockout Size

1/2" & 3/4" trade size

(22.2 & 28.6 mm)

Number of Knockouts

4

Power Company Seal/Lockout

1 location

Indoor:

Knockout Size

1/2" & 3/4" trade size

(22.2 & 28.6 mm)

Number of Knockouts

9

Power Company Seal/Lockout

2 locations

2-pole Outdoor Size:

Width, (1), 8.50" (216 mm)

Height, (2), 9.00" (229 mm)

Depth, (3), 3.74" (95 mm)

2-pole Indoor Size:

Width, (1), 8.50" (216 mm)

Height, (2), 7.00" (178 mm)

Depth, (3), 3.50" (89 mm)

5-Pole Back to Top ▲

Electrical

Control Circuit:

Current

0.2 amps

PLC Transmitter Frequency

13.3 - 15.2 kHz

Low Voltage Input Switch Loading from R terminal to all other low voltage terminals

1.2 mA

Load-Control Relays:

NOTE: Circuit 1 on the 5-Pole transceiver is only rated for 16 amps

Maximum Controlled Motor Load @ 120VAC

1 HP

Maximum Controlled Motor Load @ 208 or 240 VAC

1.5 HP

NOTE: In single-phase applications, the most effective input voltage is 240/208 VAC. 

Mechanical:

Enclosures Available:

Outdoor

Not Available

Indoor Only

Flush or Surface Mount

Features:

Indoor:

Knockouts (Small)

17 knockouts at 1/2" & 3/4" trade size

(22.23 & 28.17 mm)

Knockouts (Large)

3 knockouts at 1 1/2" & 2" trade size

(50.39 & 62.71 mm)

Power Company Seal/Lockout

2 locations

5-pole Indoor Size:

Width, (1), 10.00" (254 mm)

Height, (2), 18.00" (457 mm)

Depth, (3), 4.25" (108 mm)

3-Phase Back to Top ▲

Electrical

Control Circuit:

Current

0.2 amps

PLC Transmitter Frequency

13.3 - 15.2 kHz

Low Voltage Input Switch Loading from R terminal to all other low voltage terminals

1.2 mA

Mechanical:

Enclosures Available:

Outdoor

Surface Mount

Indoor Only

Not Available

Features:

 

Knockout Size

1/2" & 3/4" trade size

(22.23 & 28.17 mm)

Number of Knockouts

4

Power Company Seal/Lockout

1 location

3-phase Outdoor Size:

Width, (1), 12.00" (305mm)

Height, (2), 9.00" (229mm)

Depth, (3), 3.74" (95mm)

Owner's Manual 1200607 Rev 3