Location 98 (L098)

NOTE: L090 through L098 are Configuration Locations. These locations are for setting up the system and access to editing them is only available in the first 4 minutes after powering up the system

Factory

Default

Default

Range

Description / Function

0

0 to 255

All Systems

With Processor Control board rev. G or lower

Save/Restore Program Location Default Settings - Used to save preferred default values or to load previously saved or factory default values. When one of the following values is entered, the action listed is taken and the location resets to a value of zero (0).

 

Value

Action Triggered

1

Start PLC Channel Scan Testing.

20

Load configuration saved with value of 120.

30

Load configuration saved with value of 130.

40

Load configuration saved with value of 140.

50

Load configuration saved with value of 150.

NOTE: Saves can only be performed once without downloading new Firmware

99

Save configuration to be retrieved from 199.

120

Save configuration to be retrieved from 20.

130

Save configuration to be retrieved from 30.

140

Save configuration to be retrieved from 40.

150

Save configuration to be retrieved from 50.

199

Load configuration saved with value of 99.

255

Load the "Factory Defaults".

NOTE: Factory Defaults for 255 bit will be overwritten if saving the the 99 bit.

 

 

All Systems

With Processor Control board rev. H with version 2.08 software only.

Save/Restore Program Location Default Settings - Used to save preferred default values or to load previously saved or factory default values. When one of the following values is entered, the action listed is taken and the location resets to a value of zero (0).

 

Value

Action Triggered

1

Start PLC Channel Scan Testing.

20-92

Load configuration saved with value of 120-192 respectively.

NOTE: Saves can only be performed once without downloading new Firmware

99

Save configuration to be retrieved from 199.

120-192

Save configuration to be retrieved from 20-92 respectively.

199

Load configuration saved with value of 99.

255

Load the "Factory Defaults".

NOTE: Factory Defaults for 255 bit will be overwritten if saving the 99 bit.

 

 

The following values are pre-loaded in replacement circuit boards:

20

Nova Scotia

2100

21

US Standard

2100

22

Ontario "Stand-Alone"

2100

23

Ontario "Master"

2100

24

Ontario "Slave"

2100

30, 40, 50, 60, 70, 80, 90

Nova Scotia

3120, 4140, 5140...

31, 41...

US Standard

3120, 4140, 5140...

32, 42...

Ontario

3120, 4140, 5140...