Value
|
Option Selected
|
1
|
The system will not decrement L040 if "CORE FAIL" is detected.
|
2
|
"CORE FAIL" MESSAGE is not displayed even if a core fail is detected.
|
4
|
Disables proportional charging; therefore, if the system is charging, all elements are energized.
|
8
|
Enables Clock Editing Security, making it so the clock settings can only be edited for the first two (2) minutes of operation.
|
16
|
Enables space heating during a charge delay time (reference L010 subroutine 1, L026 and L041).
|
32
|
3100/4100/5100 Series Only - Enables Charge Delay (L026) for loads controlled by the peak control relay (COM, NO, NC positions on the 6-position terminal block).
|
64
|
Invert the reversing valve relay so that it can output an A Peak signal to the Master Control Module.
|
128
|
Output the percentage of Core charge with the 3 Control board relays to communicate to the Small BACNet device analog input
|