Factory Default |
Default Range |
Description / Function |
---|---|---|
0 (°F) -18 (°C) |
0 to 65 (°F) -18 to 18 (°C) |
2100/3100/4100 SERIES Freeze Protection Set Point - Temperature at which brick core charging is enabled, even during a peak control period, so heat can be delivered. This may protect an application from freeze up due to unforeseen circumstances such as external equipment failure. In the event of system failure this will not provide protection.
NOTE: An optional room temperature sensor is required if utilizing this feature with the 3100/4100. As this option may not be available in your area, please consult with a local power company representative for authorization prior to enabling.
NOTE: Freeze protection will override the ”MA” command for load management (version 2.06 or higher only) |
5100 SERIES Currently not used. |