Factory Default |
Default Range |
Description / Function |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
2100 3
3100/4100/5100 0
4200 0 |
0 to 15 |
All Systems Power Line Carrier (PLC) Channel Selection - Indicates the channel on which PLC communication will occur and MUST match the setting in the PLC transmitting device. If PLC communication is not used, a value of "0" should be entered.
NOTE: Channels 1 and 2 are original Steffes PLC communication channels and should not be used together on the same distribution transformer or in areas with a high concentration of transmitters, as cross-talk may occur.
NOTE: PLC Fail message displays after 15 minutes of no communication on startup and after 90 minutes of no communication once the system has received a communication signal. |