THIS PROCEDURE MUST BE PERFORMED BY A QUALIFIED TECHNICIAN.
THIS PROCEDURE MUST BE PERFORMED BY A QUALIFIED TECHNICIAN.
Provides outdoor temperature information to Steffes 2100, Quantum, 2000, and/or 1000 series room heaters, PLC controls, and 3100, 4100, 5100 Comfort Plus heating systems to automatically regulate brick core temperature. In heating systems that control heat pumps, it can be used for outdoor temperature lockouts for on-peak and off-peak times separately, and in 5100 Hydronic systems for the outdoor reset feature and warm weather pump shut-down.
Can be wired directly to the heating system or to a PLC control (Transceiver).
If direct wired to the system, one sensor is needed for each heater.
If wired to a PLC control, only one sensor is needed for the entire application.
Uses Low voltage, 2-conductor shielded cable (40 ft. provided).
A mounting bracket is provided or its ½” male pipe thread nipple can be used for mounting into a standard ½" trade size knockout.
1200119 Rev 12 06/14/2022