Override Option - Mini Receiver

(Power Company Permitting)

The mini receiver is available with a 90-minute override option. If the override is incorporated, it allows the use of a normally controlled device(s), such as a water heater, during a peak control time. It allows for a single override of either all connected circuits or a one zone override of circuits 1, 3, 5, and 6. This feature works well in areas using a Time-of-Use rate/control strategy. (Installation instructions for this feature are provided with the override module, item #1302070.)

An override period can be initiated during a "peak" period or if communication between the transmitter and mini receiver is lost. To do so, press and hold the override button for 2 seconds. A new 90-minute override period can be initiated any time during a current override cycle. When an override is initiated, it cannot be cancelled manually. The override will cancel itself at the end of the 90-minute override cycle or at the start of the next off-peak period, whichever comes first.

NOTE: The position of DIP switch #8 on the mini receiver circuit board will determine which relays are enabled when an override is initiated. (For more information, refer to the DIP Switch Settings.)