Room Thermostat Connections - 5100 Series

Multiple Units - Hydronic Only

NOTE: Low voltage wires MUST never enter any line voltage enclosure unless rate for line voltage.

Comfort Plus Hydronic Low Voltage Terminal Block Coding

Function

PSC Letter Code

Variable Speed Letter Code

Low Voltage Hot

R

R

Low Voltage Common (grounded)

C

C

Compressor/Stage 1 Heat Call

Y

Y1

Compressor/Stage 2 Heat Call

-

Y2

Auxiliary Heat Call

W

W/AUX

Compressor Output Stage 1

Y2

Y12

Compressor Output Stage 2

-

Y22

Fan Call

G

G

Reversing Valve Input (always energize for cooling)

O

O

Reversing Valve Output (can be energized for heating or cooling, see C006)

O2

O2

Hydronic Heat

H

H/E

Outdoor Temperature Sensor

OS & SC

Outdoor

Water Temperature Sensor

 

Water

Duct Temperature Sensor

DS & SC

Air