Initial Setup - 4200 Series

IMPORTANT

Risk of improper operation or equipment damage. Read and follow installation instructions carefully.

Remove Packaging

Remove the Information Package from the outside of the shipping box and unpackage Serenity.

Place Unit

Move Serenity into its installation location. Serenity can fit through a 24" doorway (minimum) without disassembling.

Adjust Leveling Legs

Once in place, adjust the leveling legs on the bottom of Serenity as necessary to prevent rocking. If not placed properly the system may bend or twist during the brick loading process, making element and brick core temperature sensor installation difficult. Leveling legs should be extended no more than one inch (1”).

Remove Cover

Remove the electrical panel cover by removing the screws along the edges. Locate the element screw kit.

Remove Painted Front

Remove the painted front panel of the brick storage cabinet by removing the sheet metal screws along the top, bottom, and sides of the panel. Detach by pulling the bottom of the panel forward and down.

Remove Accessories

Locate the outdoor temperature sensor, the element wiring harnesses, and the brick core temperature sensor behind the painted front panel. Set the outdoor temperature sensor aside. Disconnect the wiring harnesses and the brick core temperature sensor from their shipping positions and carefully position them to avoid damage during brick loading.

Remove Galvanized Front Cover

Remove the galvanized front panel and set it aside.

 Lift Blankets

Starting at the bottom, carefully lift the two insulation blankets, one at a time, and drape them over the top of Serenity.

NOTE: Use face mask, gloves, and long sleeved garments when handling insulation materials in compliance with generally accepted safety practices.

Remove Heating Elements

Remove the heating elements and the cardboard packaging from inside the brick core of Serenity.

Remove Front Air Channel

Remove the front air channel and set aside.

4200 Owner's Manual English 1201282 Rev 5