THIS PROCEDURE MUST BE PERFORMED BY A QUALIFIED TECHNICIAN.
HAZARDOUS VOLTAGE:
Risk of electric shock. Can cause injury or death. System may be connected to more than one branch circuit. Disconnect power to all circuits before servicing. Equipment must be installed and serviced by a qualified technician.
Disconnect Power
If applicable, disconnect power to the unit.
Remove Cover
Remove the electrical panel cover (upper left painted panel).
Locate Circuit Breakers
Locate the three circuit breakers (one 15 amp and two 60 amp).
Loosen Screws
Loosen the lug screws on all three breakers.
Insert Front Plate
Take the rear single-feed plate (with insulator) and insert the left leg of the rear single feed plate into the left lug of the 15 amp breaker. The other legs on the plate will fit into place on the right lug of the middle breaker and the left lug of the far right 60 amp breaker.
NOTE: Do NOT remove the insulator from the rear single feed plate.
Insert Back Plate
Insert the far left leg of the front single feed plate into the right lug of the 15 amp breaker. The other two legs on this plate will fit into place on the left lug of the middle breaker and the right lug of the right hand 60 amp breaker.
Tighten Screws
Make sure the single feed plates are seated into the lugs and tighten down all of the lug screws.
Attach Feed
Install one leg of the main power source into each of the top lugs of the single feed plates.
Wire Ground Lead
Wire the ground lead into the ground lug.
Inspect
Visually inspect all un-insulated live terminals to ensure there are no potential line to line and/or line to ground short circuits.
Install Cover
Install the electrical panel cover and restore power to the system.