Single Feed Kit Installation Instructions - 3100 Series

warning iconHAZARDOUS VOLTAGE:

Risk of electric shock. Can cause injury or death. System may be connected to more than one branch circuit. Disconnect power to all circuits before servicing. Equipment must be installed and serviced by a qualified technician.

Disconnect Power

If applicable, disconnect power to the unit.

Remove Cover

Remove the electrical panel cover (upper left painted panel).

Locate Circuit Breakers

Locate the three circuit breakers (one 15 amp and two 60 amp).

Loosen Screws

Loosen the lug screws on all three breakers.

Insert Front Plate

Take the rear single-feed plate (with insulator) and insert the left leg of the rear single feed plate into the left lug of the 15 amp breaker. The other legs on the plate will fit into place on the right lug of the middle breaker and the left lug of the far right 60 amp breaker.

NOTE: Do NOT remove the insulator from the rear single feed plate.

 

Insert Back Plate

Insert the far left leg of the front single feed plate into the right lug of the 15 amp breaker. The other two legs on this plate will fit into place on the left lug of the middle breaker and the right lug of the right hand 60 amp breaker.

Tighten Screws

Make sure the single feed plates are seated into the lugs and tighten down all of the lug screws.

Attach Feed

Install one leg of the main power source into each of the top lugs of the single feed plates.

Wire Ground Lead

Wire the ground lead into the ground lug.

Inspect

Visually inspect all un-insulated live terminals to ensure there are no potential line to line and/or line to ground short circuits.

Install Cover

Install the electrical panel cover and restore power to the system.

1200346 Rev 3 07/27/09