THIS PROCEDURE MUST BE PERFORMED BY A QUALIFIED TECHNICIAN.
THIS PROCEDURE MUST BE PERFORMED BY A QUALIFIED TECHNICIAN.
The 7-segment display illuminates when the transceiver is powered. A lowercase b flashes multiple times during the boot cycle. Once the boot cycle finishes, the display flashes the following in sequence:
8.8.8.
Indicates the start of the cycle of letters and numbers
P, C, or A
Indicates Peak Control Status (P = Peak, C = Off-Peak, A = Anticipated Peak)
XX
Two-digit number is the channel selected using DIP switches #2, #3, #4, and #5
EXX
"E" followed by a two-digit number indicating the error code present
oXXXF
Lower case "o" followed by 3 numbers and an F indicates outdoor temperature in Fahrenheit
iXXXF
Lower case "i" followed by 3 numbers and an F indicates indoor temperature in Fahrenheit
For example, a transceiver set to transmit mode, in off-peak, channel 3, no errors, 54 Fahrenheit outside, 70 Fahrenheit inside, would show the following:
888C03E00o054Fi070F
NOTE: In receive mode, the display will show a dash (-) for P/A/C and outdoor temperature until a signal is received.
A period after 8.8.8. on the display indicates the transceiver is connected to the internet.
Owner's Manual 1200607 Rev 3