DIP Switch 2, 3, 4 and 5 - Transmitter

TRANSMIT CHANNEL

The transmitter is capable of transmitting on one of fifteen channels. The DIP switch settings in the Steffes PLC transmitter MUST be set to match the channel setting of the receiving device(s).

To select the power line carrier communication channel desired, use the chart below and set DIP switches 2, 3, 4 and 5 to the appropriate positions. If DIP switch 2, 3, 4, and 5 are all set to the "OFF" positions, the transmitter will not transmit a power line carrier signal.

FACTORY DEFAULT = Channel Three (2 ON, 3 ON, 4 OFF, 5 OFF)

Channel

DIP

Switch #2

DIP

Switch #3

DIP

Switch #4

DIP

Switch #5

Channel

Speed

0

OFF

OFF

OFF

OFF

N/A

1

ON

OFF

OFF

OFF

SLOW

2

OFF

ON

OFF

OFF

SLOW

3

ON

ON

OFF

OFF

FAST

4

OFF

OFF

ON

OFF

FAST

5

ON

OFF

ON

OFF

FAST

6

OFF

ON

ON

OFF

FAST

7

ON

ON

ON

OFF

FAST

8

OFF

OFF

OFF

ON

FAST

9

ON

OFF

OFF

ON

FAST

10

OFF

ON

OFF

ON

FAST

11

ON

ON

OFF

ON

FAST

12

OFF

OFF

ON

ON

SLOW

13

ON

OFF

ON

ON

SLOW

14

OFF

ON

ON

ON

SLOW

15

ON

ON

ON

ON

SLOW

1. 1000/2000 Series heaters will ONLY receive on slow speed channels.

2. If multiple transmitters are installed on the same distribution transformer, do not use both channels one (1) and two (2).