Room Thermostat Connections - 5100 Series

A low voltage (24VAC) room thermostat is required for room temperature control with the Comfort Plus Hydronic system. Steffes recommends using a digital thermostat. If utilizing a mechanical thermostat, a load resistor may be necessary due to the low current draw (0.01 amps) on the heat call input circuit of the Comfort Plus system. Contact the factory for information on thermostats available from Steffes.

Please see the Table of Contents at the left or wiring diagrams below based on the needs of the application (click on the zoom in on picture icon icon to see that topic). If using a 5100-Series in conjunction with one or more other boilers as primary or secondary heat source, please contact Technical Support.

NOTE: Low voltage wires MUST never enter any line voltage enclosure.

Hydronic Heating Single Zone wiring diagramzoom in on pictureopen image

Hydronic Heating Single Zone

Stand Alone with Single Stage AC wiring diagramzoom in on pictureopen image

Stand Alone with Single Stage AC

Single Stage Heat Pump wiringzoom in on pictureopen image

Single Stage Heat Pump

Two Stage Heat Pump wiringzoom in on pictureopen image

Two Stage Heat Pump

Also, Special Applications:

wiring for multiple 5100 Units in Tandemzoom in on pictureopen image

Multiple Units in Tandem

Multiple Heat Pump operation with heat pumpszoom in on pictureopen image

Multiple Heat Pumps (PSC-Style Shown)

Floor Heat in Cooling Seasonzoom in on pictureopen image

Floor Heat in Cooling Season

5100 Install Guide 1206115 Rev 0