Model |
4120 |
4130 |
4140 |
||||
|---|---|---|---|---|---|---|---|
|
Charging Input (kW) |
14.0 |
19.2 |
24.8 |
28.8 |
37.2 |
38.4 |
45.6 |
|
Single Feed: Minimum Circuit Ampacity (240V Systems) (Includes 25% Derate for Continuous Load) |
82 |
109 |
138 |
159 |
202 |
209 |
246 |
|
Element Current Draw |
59 |
80 |
104 |
120 |
155 |
160 |
190 |
|
Element Circuits Required (amps) (240V System - Multiple Feed) |
1-20 2-30 |
1-30 2-40 |
1-40 2-50 |
4-40 |
4-50 |
4-50 |
4-60 |
|
Number of Elements |
8 |
12 |
16 |
||||
|
Maximum Core and Supply Blower Load |
7 AMPS |
||||||
|
Blowers / Controls Voltage |
240V/208V / 60 Hz |
||||||
|
Element Voltage |
240V standard (208V optional as special factory order) / 60 Hz NOTE: The 240V Element circuits can be connected to 208V in standard configurations; however, the charging input of the system will be derated by 25%. |
||||||
|
Storage Capacity kWh BTU |
120 409,440 |
180 614,160 |
240 818,880 |
||||
|
Dimensions (W x D x H in inches) w/o Ducting w/ Factory-Built Ducting (1/2 HP) w/ Factory-Built Ducting (3/4 HP) |
29.2 x 47.4 x 46 77.6 x 47.4 x 46 82.1 x 47.4 x 46 |
29.2 x 47.4 x 57 77.6 x 47.4 x 57 82.1 x 47.4 x 57 |
29.2 x 47.4 x 68 77.6 x 47.4 x 68 82.1 x 47.4 x 68 |
||||
|
Duct Openings (inches) Supply Air Outlet (1/2 HP) Supply Air Outlet (3/4 HP) Return Air Inlet: |
18 x 22.6 22.5 x 22.6 10.5 x 22.6 (in heater) or 26.2 x 22.25 (if using factory-built plenum) |
||||||
|
Maximum Coil Size (W x D x H in inches) The return plenum is optional. Dimensions listed are those that the return air plenum can accommodate. For large coils, the return plenum must be installer supplied. The Comfort Plus does not include the indoor coil or the outdoor compressor system as standard equipment. • ½ HP variable speed accommodates most 1 ½ to 4 ton heating/cooling systems. • ¾ or 1 HP variable speed accommodates most 3 to 5 ton heating/cooling systems. • Equipment modifications are required to fit larger coils. Capacity Front Access Dimensions Inner Dimensions |
1 1/2 to 5 TON 25.5 x 22 x 30 26 x 22 x 31 |
||||||
|
Approximate Heater Weight |
392 lb |
476 lb |
531 lb |
||||
|
Approximate Brick Weight |
1,702 lb |
2,458 lb |
3,214 lb |
||||
|
Approximate Installed Weight w/o Plenum |
2,094 lb |
2,934 lb |
3,745 lb |
||||
|
Number of Brick Whole Brick Half Brick |
105 6 |
150 12 |
198 12 |
||||
|
Supply Air Delivery (Field Selectable) 1/2 HP Variable Speed CFM Rating 3/4 HP Variable Speed CFM Rating |
1000, 1200, 1400, 1600 1200, 1400, 1600, 2000 |
||||||
|
Maximum Maintainable Heat Loss (BTU/hr) Contact a local Steffes dealer or power company for assistance in selecting an appropriately sized system for your specific charge strategy. The 6/4/6/8 strategy listed is 8 hours off-peak at night plus 4 hours off-peak midday. (The heating ability figures listed have a heat use allowance factored in for sizing purposes. Average BTU/hr. delivery rate is the listed value multiplied by .78 heat use factor.) 8 Consecutive Charge Hours 12 Consecutive Charge Hours 6/4/6/8 Charge Strategy |
20,414 30,621 30,621 |
27,996 41,994 41,994 |
34,175 45,566 54,242 |
41,994 62,991 62,991 |
49,212 65,615 81,363 |
55,992 83,988 83,988 |
65,615 87,487 99,735 |
1206129 Rev 0, 03/13/2025