Accessing Configuration Menu

Steffes heating systems have a Configuration Menu, which allows the system to be customized to the power company and consumers needs. This menu can be accessed on start-up and allows configuration settings to be easily adjusted.

NOTE: Upon power up of the heating system, entry into the Configuration Menu is automatically provided for the first two (2) minutes of operation.  After this time, entry into the Configuration Menu is denied unless the system's 15 amp breaker is powered off and back on again.

  1. Energize the system. Access to the Configuration Menu is allowed for the first two (2) minutes of operation. If the system has been energized for more than two (2) minutes, the 15 amp circuit breaker must be powered off and back on to gain access to this menu.
  2. Press and release the M button until faceplate displays "CONF", as shown.
  3. Press the up arrow once and the faceplate will display "C000". The faceplate will flash between "C000" and the corresponding configuration value.
  4. If necessary, edit the configuration value by pressing and holding the M button while using the up or the down arrow button to change the value.
  5. Once the value is correct, release the buttons and press the up arrow button to go to the next configuration (C001, C002, etc.)
  6. Repeat steps 4 through 5 until all configuration settings have been adjusted to the desired values.
  7. Once configured, use the down arrow to leave the Configuration Menu.