Charge Control Override - 2100/3100/4100/4200/5100 Series

The Steffes ETS systems are equipped with a charge control override feature that allows the user to force the system to target a full core charge level. This override can be initiated or cancelled at any time. If an override is initiated, the system targets a full core charge level during the next off-peak period. It continues to charge during off-peak hours until it achieves full (maximum) core charge (at least 90%) or until the override is cancelled.  Once full charge is achieved or the override is cancelled, the system charges according to its standard configuration.

Initiate the Charge Control Override

  1. Press and hold the M, the up arrow, and the down arrow buttons at the same time.
  2. The faceplate display will flash "FULL" and "ON". Continue to hold all three buttons until "ON" displays continuously on the faceplate.
  3. Release the buttons. The override is now enabled. The faceplate will return to displaying its standard operating mode

Cancel the Charge Control Override

  1. Press and hold the M, the up arrow, and the down arrow buttons at the same time.
  2. The faceplate display will flash "FULL" and "OFF". Continue to hold all three buttons until "OFF" displays continuously on the faceplate.
  3. Release the buttons. The override is now cancelled. The faceplate will return to displaying its standard operating mode.
   

NOTE: The charge control override DOES NOT turn elements on during a peak period.

This feature will cancel if power is interrupted.